Home > Products > Wire and Cable > Electric Submersible Pump Cable > QYPN QYEN (QYPF) Type Submersible Oil Power Cable

QYPN QYEN (QYPF) Type Submersible Oil Power Cable

APPLICATION

This product is suitable for supplying power to submersible oil pump units with rated voltage less than 3KV or less than 6KV.

 

OPERATING CHARACTERISTICS

Conductor long-term working Temperature90°C, with excellent oil and heat resistance and corrosion resistance.

 

TYPE AND NAME

Modified polypropylene or EPDM insulation, nitrile rubber sheath, PTFE tape / fiber tape wrap, communication cable, galvanized (stainless steel, Monel) Steel strip armored flat submersible pump power cable.

 

PRODUCTION RANGE OF CABLE

Voltage:3KV 4KV 5KV 6KV.
Temperature: 90°C/205°F.
Implementation standards: GB/T16750-2015, APIRP 11S6

Technical Specifications

Cores

 

Cores

Nominal cross section area AWG/mm²

Number of conduct or roots diametermm

mm

Conductor DC resistance20°C≤Ω/Km

Insulation nominal thickness mm

Nominal thickness of the sheath mm

Cable overall size and weight(flat cable)

3KV

6KV

Tin-plated

3KV

5KV

3KV

5KV

mmxmm

Kg/km

mmxmm

Kg/Km

Power

Unit

3

5/10

1/4.62

1.16

1.9

2.3

1.3

1.3

14x37

1278

18x42

1390

3

4/20

1/5.19

0.86

1.9

2.3

1.3

1.3

15x39

1449

19x44

1580

3

2/33.5

1/6.54

0.56

1.9

2.3

1.3

1.3

16x44

1643

21x50

1760

3

1/42.5

1/7.35

0.44

1.9

2.3

1.3

1.3

17x47

2158

22x54

2270

Control

unit

1-3

0.4-1.0

7/0.27-0.43

45-18.1

0.6

1.3

140

 

Nominal cross section area mm²/AWG

Conductor nominal diameter

1.9mm Insulation resistance MΩ·Km

1.9mm Leakage current μA/ (Kv·Km)

2.3mm Insulation resistance MΩ·Km

2.3mm Leakage current μA/ (Kv·Km)

DC with stand voltage 5 minutes

3KV

5KV

16/5

4.62

3800

0.27

4082

0.24

27

35

20/4

5.19

3380

0.31

3738

0.27

27

35

33.5/2

6.54

2650

0.38

3121

0.32

27

35

42.5/1

7.35

2405

0.42

2841

0.35

27

35

 

I DELIVERY REQUIREMENTS

Can be delivered in a minimum of 1000 meters, packed in all-steel corrugated trays.

 

I STORAGE AND TRANSPORTATION INSTRUCTIONS

For cables delivered in rolls, the outermost cable, the distance from the edge of the diameterof the corrugated all-steel cable tray is 100mm lower, and the cable is not allowed to bebumped or twisted. Both ends of the cable do moisture-proof.

FAQs

Q1: What advantages do these products offer compared to standard copper wires?

They provide superior electrical insulation, high thermal stability, excellent mechanical strength, strong resistance to moisture, radiation, and thermal shock, making them suitable for extreme and high-demand environments.

Q2: Can the products be customized according to specific requirements?

Yes. We offer customized solutions in terms of conductor size, insulation structure, temperature class, voltage level, and mechanical performance according to customer application needs.

Q3: What temperature ratings are available?

Depending on the insulation system, the products are generally suitable for Class F (155°C), Class H (180°C), and higher temperature environments, ensuring stable performance under continuous thermal stress.

Q4: What are the main applications of these products?

They are widely used in high-efficiency motors, generators, transformers, submersible motor systems, rail transit traction motors, wind power equipment, and industrial electrical systems requiring high reliability.

Q5: What types of products are included in this series?

This product range includes enameled copper flat wire, fiberglass insulated wires, film-wrapped copper wires, and high-performance composite insulated copper flat and round wires designed for demanding electrical applications.

Q6: What are the main advantages of hollow conductor products compared to solid wires?

Hollow conductors provide efficient internal cooling, improved thermal management, higher power density capability, and better stability in high-load continuous operation environments.

Q7: Can the size and structure be customized?

Yes. Outer diameter, inner diameter, wall thickness, conductor shape (round or flat), and insulation structure can all be customized according to customer technical requirements.

Q8: What are the main material options available?

The product range includes stainless steel hollow wire, oxygen-free copper hollow wire, and various insulated versions with composite structures such as polyimide F46 film, fiberglass, and polyester insulation systems.

Q9: What cooling media can be used inside the hollow conductors?

The products are compatible with common cooling media such as water, oil, and other industrial cooling fluids, depending on the system design and operating conditions.

Q10: What are these hollow conductor products mainly used for?

These hollow conductors are mainly used in high-power electrical systems requiring internal cooling, such as electric motors, generators, traction systems, and industrial equipment with water or oil cooling structures.

HOW CAN WE HELP YOU?

We offer customization to meet your specific needs. Our expert team will collaborate with you to develop the perfect product for you

Add: Baoshida Group Industrial Park, No. 8 Kaiyuan Road, East Section of North Industrial Road, Licheng District, Jinan City, Shandong Province, China

Quick Link

Quick Link

Contact Us

Contact Us

+86 13335151337

+86 13335151337

16675765504

Get The Latest News

Get The Latest News

Copyright @ All Rights Reserved | Sitemap

0.166294s