APPLICATION
This product is suitable for supplying power to submersible oil pump units with rated voltage less than 3KV or less than 6KV.
OPERATING CHARACTERISTICS
Conductor long-term working Temperature90°C, with excellent oil and heat resistance and corrosion resistance.
TYPE AND NAME
Modified polypropylene or EPDM insulation, nitrile rubber sheath, PTFE tape / fiber tape wrap, communication cable, galvanized (stainless steel, Monel) Steel strip armored flat submersible pump power cable.
PRODUCTION RANGE OF CABLE
Voltage:3KV 4KV 5KV 6KV.
Temperature: 90°C/205°F.
Implementation standards: GB/T16750-2015, APIRP 11S6
Technical Specifications
|
Cores
|
Cores |
Nominal cross section area AWG/mm² |
Number of conduct or roots diametermm mm |
Conductor DC resistance20°C≤Ω/Km |
Insulation nominal thickness mm |
Nominal thickness of the sheath mm |
Cable overall size and weight(flat cable) |
|||||
|
3KV |
6KV |
|||||||||||
|
Tin-plated |
3KV |
5KV |
3KV |
5KV |
mmxmm |
Kg/km |
mmxmm |
Kg/Km |
||||
|
Power Unit |
3 |
5/10 |
1/4.62 |
1.16 |
1.9 |
2.3 |
1.3 |
1.3 |
14x37 |
1278 |
18x42 |
1390 |
|
3 |
4/20 |
1/5.19 |
0.86 |
1.9 |
2.3 |
1.3 |
1.3 |
15x39 |
1449 |
19x44 |
1580 |
|
|
3 |
2/33.5 |
1/6.54 |
0.56 |
1.9 |
2.3 |
1.3 |
1.3 |
16x44 |
1643 |
21x50 |
1760 |
|
|
3 |
1/42.5 |
1/7.35 |
0.44 |
1.9 |
2.3 |
1.3 |
1.3 |
17x47 |
2158 |
22x54 |
2270 |
|
|
Control unit |
1-3 |
0.4-1.0 |
7/0.27-0.43 |
45-18.1 |
0.6 |
1.3 |
140 |
|||||
|
Nominal cross section area mm²/AWG |
Conductor nominal diameter |
1.9mm Insulation resistance MΩ·Km |
1.9mm Leakage current μA/ (Kv·Km) |
2.3mm Insulation resistance MΩ·Km |
2.3mm Leakage current μA/ (Kv·Km) |
DC with stand voltage 5 minutes |
|
|
3KV |
5KV |
||||||
|
16/5 |
4.62 |
3800 |
0.27 |
4082 |
0.24 |
27 |
35 |
|
20/4 |
5.19 |
3380 |
0.31 |
3738 |
0.27 |
27 |
35 |
|
33.5/2 |
6.54 |
2650 |
0.38 |
3121 |
0.32 |
27 |
35 |
|
42.5/1 |
7.35 |
2405 |
0.42 |
2841 |
0.35 |
27 |
35 |
I DELIVERY REQUIREMENTS
Can be delivered in a minimum of 1000 meters, packed in all-steel corrugated trays.
I STORAGE AND TRANSPORTATION INSTRUCTIONS
For cables delivered in rolls, the outermost cable, the distance from the edge of the diameterof the corrugated all-steel cable tray is 100mm lower, and the cable is not allowed to bebumped or twisted. Both ends of the cable do moisture-proof.
FAQs
Q1: What advantages do these products offer compared to standard copper wires?
They provide superior electrical insulation, high thermal stability, excellent mechanical strength, strong resistance to moisture, radiation, and thermal shock, making them suitable for extreme and high-demand environments.
Q2: Can the products be customized according to specific requirements?
Yes. We offer customized solutions in terms of conductor size, insulation structure, temperature class, voltage level, and mechanical performance according to customer application needs.
Q3: What temperature ratings are available?
Depending on the insulation system, the products are generally suitable for Class F (155°C), Class H (180°C), and higher temperature environments, ensuring stable performance under continuous thermal stress.
Q4: What are the main applications of these products?
They are widely used in high-efficiency motors, generators, transformers, submersible motor systems, rail transit traction motors, wind power equipment, and industrial electrical systems requiring high reliability.
Q5: What types of products are included in this series?
This product range includes enameled copper flat wire, fiberglass insulated wires, film-wrapped copper wires, and high-performance composite insulated copper flat and round wires designed for demanding electrical applications.
Q6: What are the main advantages of hollow conductor products compared to solid wires?
Hollow conductors provide efficient internal cooling, improved thermal management, higher power density capability, and better stability in high-load continuous operation environments.
Q7: Can the size and structure be customized?
Yes. Outer diameter, inner diameter, wall thickness, conductor shape (round or flat), and insulation structure can all be customized according to customer technical requirements.
Q8: What are the main material options available?
The product range includes stainless steel hollow wire, oxygen-free copper hollow wire, and various insulated versions with composite structures such as polyimide F46 film, fiberglass, and polyester insulation systems.
Q9: What cooling media can be used inside the hollow conductors?
The products are compatible with common cooling media such as water, oil, and other industrial cooling fluids, depending on the system design and operating conditions.
Q10: What are these hollow conductor products mainly used for?
These hollow conductors are mainly used in high-power electrical systems requiring internal cooling, such as electric motors, generators, traction systems, and industrial equipment with water or oil cooling structures.