+86 13335151337
The product is independently upgraded and developed by innovative technology, and the quality of insulation structure is more stable. After bending, there is no damage to the insulation layer, which effectively avoids the most vulnerable insulation point damage when the product is transposed. The tensile adhesion is excellent, which can withstand the large inclination angle displacement when the coil is bent, and avoid the tearing of the insulation layer. The electrical performance is stable with high breakdown value. The three-dimensional angle is uniform, which ensures the uniform flow rate of internal water cooling or oil cooling, and has good mechanical performance and sealing performance.With higher mechanical property, overload capacity and resistance to heat and humidity, this product is applicable to the windings of large and medium-sized high-voltage motors and generators, transformers and various electric devices.
Technical Specifications:
The following table presents typical technical specifications for the standard Double Glass-fiber Covered Rectangular Copper Wires. Specifications may vary depending on operating conditions and system requirements. The product is designed to ensure stable electrical performance, durability, and safety in demanding industrial applications.
Technical Specifications
|
Model&Specification |
|||||
|
Type |
Dimensions |
Name |
Thermalindex |
||
|
GLEB axb GB/T 7672.2-2008 |
Thickness a:0.08~5.60mm Width b:2.00~16.00mm |
Glass-fiber wound resin impregnated, bare rectangular copper wire, temperature index 130 |
130 |
||
|
GLEB axb GB/T 7672.3-2008 |
Glass-fiber wound resin impregnated, bare rectangular copper wire, temperature index 155 |
155 |
|||
|
GLEB axb GB/T 7672.4-2008 |
Glass-fiber wound resin impregnated, bare rectangular copper wire, temperature index 180 |
180 |
|||
|
GLEB axb GB/T 7672.5-2008 |
Glass-fiber wound resin impregnated, bare rectangular copper wire, temperature index 200 |
200 |
|||
|
Technical parameters |
|||||
|
Items |
Technical indexes |
|
Testing standards |
||
|
Dimensions |
Meet the Chapter 4 in GB/T 7672.1-2008 |
GB/T 4074.2-2008 |
|||
|
Resistance |
Meet the Chapter 5 in GB/T 7672.1-2008 |
GB/T 4074.5-2008 |
|||
|
Elongation |
Thickness,mm |
Elongation, % |
GB/T 4074.3-2008 |
||
|
a≤2.50 |
>30 |
||||
|
a>2.50 |
≥32 |
||||
|
Resilience |
Maximum spring-back angle is less than 5.5° |
GB/T 4074.3-2008 |
|||
|
Adhesiveness |
Strength 10%, the coverings without losing adhesiveness |
GB/T 4074.3-2008 |
|||
|
Bend test |
Nominal dimension, mm |
Mandrel diameter, mm |
After flatwise and edgewise bend tests, the coverings to be without crack. |
GB/T 4074.3-2008 |
|
|
2.00≤b≤8.00 |
10b |
||||
|
8.00<b≤16.00 |
15b |
||||
|
0.80≤a≤5.60 |
10a |
||||
|
Breakdown voltage |
Nominal insulation thickness (mm) |
Breakdown voltage(V) |
GB/T 4074.5 |
||
|
0.20 |
≥300 |
||||
|
0.40 |
≥400 |
||||
Customization Capabilities
We offer flexible customization solutions to meet diverse application requirements in electrical and industrial fields. From structural design to insulation performance, every aspect can be tailored to ensure optimal conductivity, mechanical strength, and thermal reliability.
1. Conductor Dimensions & Hollow Structure
Outer width, thickness, and inner cavity dimensions can be precisely customized to meet specific electrical design and cooling requirements, ensuring optimal current capacity and heat dissipation.
2. Glass-Fiber Insulation Configuration
Double glass-fiber wrapping can be customized in terms of thickness, layering method, and wrapping density to meet different insulation grades and thermal class requirements.
3. Thermal & Electrical Performance
Temperature index, dielectric strength, and overall insulation performance can be adjusted based on application needs, ensuring stable operation under high-temperature or high-load conditions.
4. Surface Treatment & Processing Options
Available with resin impregnation, surface finishing, and additional treatments to enhance adhesion, mechanical durability, and resistance to environmental factors.
FAQs
Q1: What are the main applications of Double Glass-fiber Covered Rectangular Copper Wires?
They are widely used in windings of large and medium-sized high-voltage motors, generators, transformers, and various electrical equipment.
Q2: What are the core advantages of double glass-fiber covered copper wires?
They feature stable insulation, no damage after bending, excellent tensile adhesion, high breakdown voltage, good mechanical properties, and strong heat & humidity resistance.
Q3: Can this product be used in transposed conductors?
Yes, its insulation structure is specially designed to avoid insulation damage during transposition and coil bending.
Q4: Is customization supported for insulation and dimensions?
Yes, we can customize insulation thickness, wrapping structure, conductor size, hollow structure, and thermal/electrical performance.
Q5: What is the insulation structure of this product?
It adopts a double glass-fiber covered design with stable insulation, high adhesion, and excellent resistance to tearing and displacement.
HOW CAN WE HELP YOU?
We offer customization to meet your specific needs. Our expert team will collaborate with you to develop the perfect product for you
Add: Baoshida Group Industrial Park, No. 8 Kaiyuan Road, East Section of North Industrial Road, Licheng District, Jinan City, Shandong Province, China
Contact Us
Get The Latest News
Get The Latest News